Sign in →

Test Code TRAN Transferrin

Specimen and Container/Tube

Specimen Type: Plasma

Preferred Specimen: Li-Heparin Mint Green Top

Other Acceptable specimens: Serum/Gold Top, Serum/Red Top

Specimen Handling and Transport Instructions

UCMC Onsite Instructions: 

Collect specimen per standard collection procedure and send to laboratory immediately. 

 

UCMC Offsite and UC MedLab Outreach Instructions: 

  • Samples should be centrifuged within 2 hours of collection.
  • Centrifuge specimens at >2500 x g for 10 minutes at room temperature.
  • Aliquot sample into plastic transport tube containing a minimum of 0.2 mL of specimen.
  • Samples must be sent room temperature at 15-25oC.

Rejection Criteria

  • Common specimen rejected situations include: incorrect specimen type, insufficient volume, missing or incomplete specimen identifiers, incorrect specimen transport, or specimens outside stability limits. 
  • Specimens that are clotted or grossly hemolyzed.
  • Specimens that were transported unspun/whole blood and draw time is greater than 6 hours.

Reference Values

 

Test

Age

Sex

Reference Range

Transferrin

All

All

168-302 mg/dL

Critical Values

Analyte

Unit

Low

High

Age

N/A

N/A

N/A

N/A

N/A

CPT Codes

84466

LOINC Codes

3034-6

Volume

Preferred Volume: 0.5 mL

Minimum Volume: 0.2 mL

Specimen Stability

Storage Temperature

Stability

Room temperature

8 days

Refrigerated

8 days

Frozen

6 months

Collection Instructions

Collect specimen per standard laboratory collection procedures. 

 

Test Components

Transferrin
 

Clinical Indications

Transferrin is the iron transport protein in serum. In cases of iron deficiency, the degree of transferrin saturation appears to be an extremely sensitive indicator of functional iron depletion. The ferritin levels are depressed when there is a deficiency of storage iron. In sideropenia, an iron deficiency can be excluded if the serum transferrin concentration is low, as in inflammations or, less commonly, in cases of ascorbic acid deficiency. In screening for hereditary hemochromatosis, transferrin saturation provides a better indication of the homozygous genotype than does ferritin. The treatment of anemia with erythropoietin in patients with renal failure is only effective when sufficient depot iron is present. The best monitoring procedure is to determine transferrin saturation during therapy. Transferrin saturation in conjunction with ferritin gives a conclusive prediction of the exclusion of iron overloading in patients with chronic liver disease.

Methodology

Immunoturbidimetric Assay

Additional Information

Turnaround Time

Turnaround times are relative to the time the specimen is received in the test laboratory. 

 

STAT Turnaround Time: 1 hour

Routine Turnaround Time: 4 hours

Testing Schedule: 24/7

Last Review Date