Test Code AMITR Amikacin, Trough
Specimen and Container/Tube
Specimen Type: Serum
Preferred Specimen: Red Top
Other Acceptable specimens: Serum/Gold Top
Specimen Stability
|
Storage Temperature |
Stability |
|
Room temperature |
8 hours |
|
Refrigerated |
2 days |
|
Frozen |
4 weeks |
Collection Instructions
Collect specimen per standard laboratory collection procedures.
Specimen Handling and Transport Instructions
UCMC Onsite Instructions:
Collect specimen per standard collection procedure and send to laboratory immediately.
UCMC Offsite and UC MedLab Outreach Instructions:
- Samples should be centrifuged within 2 hours of collection.
- Centrifuge specimens at >2500 x g for 10 minutes at room temperature.
- Aliquot sample into plastic transport tube containing a minimum of 0.2 mL of specimen.
- Samples must be sent refrigerated at 2-8oC.
Rejection Criteria
- Common specimen rejected situations include: incorrect specimen type, insufficient volume, missing or incomplete specimen identifiers, incorrect specimen transport, or specimens outside stability limits.
- Specimens that are clotted or grossly hemolyzed.
- Specimens that were transported unspun/whole blood and draw time is greater than 6 hours.
Reference Values
|
Test |
Age |
Sex |
Reference Range |
|
Amikacin |
All |
All |
<4 μg/mL |
Critical Values
|
Analyte |
Unit |
Low |
High |
Age |
|
Amikacin |
μg/mL |
N/A |
>10.0 |
All |
Turnaround Time
Turnaround times are relative to the time the specimen is received in the test laboratory.
STAT Turnaround Time: 1 hour
Routine Turnaround Time: 4 hours
Testing Schedule: 24/7
Clinical Indications
Determination of serum or plasma drug levels is required to achieve optimum therapeutic efficacy and minimize toxicity.
Test Components
Amikacin
CPT Codes
80150
LOINC Codes
3321-7
Methodology
Kinetic Interaction of Microparticles in solution (KIMS) (Roche Diagnostics)
Synonyms/Keyword Search
N/A
Additional Information
- Results should always be assessed in conjunction with patient's medical history, clinical examination and other findings.
- Determination of serum or plasma drug levels is required to achieve optimum therapeutic efficacy and minimize toxicity.
- Serum tubes containing separating gel may be used if received in Labortory Services within 2 hours after collection.
- Collection time varies dependent upon desired measurement of peak or trough values.
Last Review Date
8/14/2024
Volume
Preferred Volume: 0.5 mL
Minimum Volume: 0.2 mL