Test Code BDZU Benzodiazepines, Qualitative Screen, Urine
Specimen and Container/Tube
Specimen Type: Urine, Random Collection
Preferred Specimen: Sterile Plastic Container
Other Acceptable specimens: Sterile Clean Glass Container
Specimen Handling and Transport Instructions
UCMC Onsite Instructions:
- Collect specimen per standard collection procedure and send to laboratory immediately.
- No preservatives or additives.
UCMC Offsite and UC MedLab Outreach Instructions:
- Samples should be centrifuged within 2 hours of collection
- No preservatives or additives
- Centrifuge specimens at >2500 x g for 10 minutes at room temperature.
- Aliquot urine into plastic tube containing a minimum of 1.0 mL of specimen.
- Urine samples must then be sent refrigerated at 2-8oC.
Rejection Criteria
- Common specimen rejected situations include: incorrect specimen type, insufficient volume, missing or incomplete specimen identifiers, incorrect specimen transport, or specimens outside stability limits.
- Specimens that are collected with preservatives or additives.
Reference Values
Test |
Age |
Sex |
Reference Range |
Benzodiazepine |
All |
All |
None Detected |
Critical Values
Analyte |
Unit |
Low |
High |
Age |
N/A |
N/A |
N/A |
N/A |
N/A |
CPT Codes
80307
LOINC Codes
14316-4
Volume
Preferred Volume: 3.0 mL
Minimum Volume: 1.0 mL
Specimen Stability
Storage Temperature |
Stability |
Room temperature |
Not Acceptable |
Refrigerated |
5 Days |
Frozen |
30 Days |
Collection Instructions
- Collect specimen per standard laboratory collection procedures.
- No preservatives or additives.
Test Components
Benzodiazepine
Clinical Indications
- For medical purposes only.
- Qualitative screening for benzodiazepine in urine
- This test must not be used for employee drug testing or other purposes requiring a chain of custody handling procedure.
Methodology
Kinetic Interaction of Microparticles in solution (KIMS) (Roche Diagnostics)
Additional Information
- Results should always be assessed in conjunction with patient's medical history, clinical examination and other findings.
- Also included in urine toxicology screen; EDS order code.
- The Emergency Drug Screen (EDS) includes screening tests for Ethanol, Amphetamines, Barbiturates, Benzodiazepines, Cocaine Metabolite, Opiates, Phencyclidine, Methadone Metabolite, Fentanyl and Oxycodone.
- All positive results are considered presumptive unless confirmed by an alternate method. Cutoff values used to discern positive from None Detected: 300 ng/mL or greater. The concentration of drug detected cannot be estimated by this qualitative method.
Turnaround Time
Turnaround times are relative to the time the specimen is received in the test laboratory.
STAT Turnaround Time: 1 hour
Routine Turnaround Time: 4 hours
Testing Schedule: 24/7
Synonyms/Keyword Search
DAT: Drugs of Abuse Testing, Benzo
Last Review Date
8/19/2024