Test Code CMVUR Cytomegalovirus (CMV), Qualitative PCR, Urine
Additional Codes
CMV urine
CMV
Cytomegalovirus
Specimen and Container/Tube
Urine, random sample
Sterile container. Boric acid transport tubes are NOT acceptable.
Specimen Handling and Transport Instructions
Transpot Instructions
See UCMC Collection Instructions
Rejection Criteria
Volumes <750uL
Reference Values
Test Limitations
Detection limit = 34.5 IU/mL
Critical Values
All positive culture
|
|
|
|
All |
Turnaround Time
Day(s) Performed
Monday through Friday
STAT DAY(S) AND TIME(S) PERFORMED
Not Available
CPT Codes
87496
LOINC Codes
30687496
Volume
Preferred Volume
1.5mL
Specimen Minimum Volume
750 uL
Pediatric Volume
750uL
Collection Instructions
Offsite Collection Instructions
See UCMC collection instructions.
UCMC Collection Instructions
Specimen Source: Clean voided, clean catch.Early morning specimen is best.
Specimen Collection:
Female Cleansing Instructions: Stand in a squatting position over the toilet. Separate the folds of the skin around the urinary opening. Cleanse the area around the opening with the first castile soap towelette. Repeat using a second clean towelette. Urinate the first portion of urine into the toilet. As you continue to urinate, bring the collection cup into the midstream to collect the urine sample. Do not touch the inside or lip of the cup. Urinate the remainder of urine into the toilet. Place the blue cap onto the BD Vacutainer Urine Collection Cup.Return the sample of the healthcare worker.
Male Cleansing Instructions: Cleanse the end of the penis with the first castile soap towelette beginning at the urethral opening and working away from it (the foreskin of an uncircumsized male must be retracted). Repeat using a second clean towelette. Urinate the first portion of urine into the toilet. As you continue to urinate, bring the collection cup into the midstream to collect the sample. Do not touch the inside or lip of the cup. Urinate the remainder of urine into the toilet. Place the blue cap onto the BD Vacutainer Urine Collection Cup. Return the sample to the healthcare worker. Healthcare worker transfers sample from cup into white top screw-cap container.
Specimen Transport: <2 hr ambient, 7 days refrigerated
See Microbiology Specimen Collection:
- Category “Urine”, Table 1 BACTERIOLOGY, CHLAMYDIA, MYCOLOGY, MYCOBACTERIOLOGY (AFB), VIROLOGY
Test Components
Urine, random sample
Methodology
PCR testing performed on the Roche 6800
Synonyms/Search Keywords
CMV urine
CMV
Cytomegalovirus
Last Reviewed Date
08/15/2022
Additional Information
Test Limitations
Detection limit = 34.5 IU/mL